When three NEO ES series SXN403-E units and our FX411N units are stacked, space efficiency can be reduced by up to 80%.

Not only does this make effective use of space, but it also greatly contributes to shortening development time by allowing tests to be performed under three different conditions simultaneously.
All models come standard with a DC inverter rotary refrigerator, achieving significant reductions in power consumption and improved performance, such as shorter temperature drop times, all in one refrigerator.

When the temperature and humidity are stable, the refrigeration capacity is reduced as much as possible, which reduces the heater output for heating and humidification and reduces power consumption.

The temperature and humidity are maintained by adjusting the refrigeration capacity to follow changes in the heat load inside the tank.


By adopting a high-performance, highly reliable single-stage refrigeration circuit, the upper limit of the ambient temperature at which the unit can operate has been expanded from +35°C to +40°C.Furthermore, it has become possible to reach the minimum temperature (-40°C) even at an ambient temperature of +35°C.

The temperature drop time when the DC inverter rotary refrigerator is operating at full power has been significantly reduced. After the temperature drop, the refrigerator capacity is reduced as much as possible during stable operation, contributing to energy savings.
*These are actual measurements and are not guaranteed values.

Our unique refrigeration circuit (patent pending) fully utilizes the properties of the low GWP refrigerant R448A, significantly improving the allowable heat generation. This allows for tests where maintaining the temperature is difficult in conventional small chambers, such as when samples generate heat.

The latest DC inverter rotary chiller is installed as standard. The efficiency of the chiller system and the unique refrigerant flow control using an electronic expansion valve optimize chiller capacity, resulting in a significant reduction in power consumption.

It is possible to control normal temperature and humidity, which is difficult to achieve with a general small tank. It is also possible to operate at a maximum humidification of 98%RH.

The consumption rate has been significantly reduced by optimizing and reviewing the humidification water supply system.

This setting device is configured with a minimum number of keys and prioritizes simple operation. In addition to constant operation, simple programs can be set using only the main unit. Standard pattern operation is also possible. In addition, by using the newly developed software NLPE (Neo Local Program Editor), you can create your own test conditions in an environment separate from the tester.

Each pattern can have 26 steps. Nine different program patterns can be input and saved, and each program can be repeated up to 99 times.

The LCD touch panel keypad was developed specifically for the HIFLEX NEO. It can operate multiple HIFLEX NEOs, and is easy to operate despite its many functions, including detailed settings and test data downloads.

The built-in chamber management application software can be accessed directly from a PC or tablet, eliminating the need for dedicated software like in the past, and creating a comfortable testing environment.
| Model | SXN401-E | SXN402-E | SXN403-E | SXN412-E |
|---|---|---|---|---|
| Number of steps | 1 | 2 | 3 | 2 |
| Inner dimensions (W x H x D mm) | 500×350×350 | 500×350×350 × 2 | 500×350×350 × 3 | 600×600×500 × 2 |
| Contents (L) | 61 | 61 × 2 | 61 × 3 | 180 × 2 |
| Temperature range | -40℃~+100℃ [+150℃] | -40℃~+100℃ [+150℃] | -40℃~+100℃ [+150℃] | -40℃~+100℃ [+150℃] |
| Humidity Range | 20%RH to 98%RH | 20%RH to 98%RH | 20%RH to 98%RH | 20%RH to 98%RH |
| Model | SLN401-E | SLN402-E | SLN403-E | SLN412-E |
|---|---|---|---|---|
| Number of steps | 1 | 2 | 3 | 2 |
| Inner dimensions (W x H x D mm) | 500×350×350 | 500×350×350 × 2 | 500×350×350 × 3 | 600×600×500 × 2 |
| Contents (L) | 61 | 61 × 2 | 61 × 3 | 180 × 2 |
| Temperature range | -40℃~+100℃ [+150℃] | -40℃~+100℃ [+150℃] | -40℃~+100℃ [+150℃] | -40℃~+100℃ [+150℃] |
| Humidity Range | – | – | – | – |