Views:38
WINTECH realizes temperature recovery in the shortest time possible, which is an important basic function of temperature cycle testers, by optimizing the cooling and heating circuit system with excellent cooling and heating exchange efficiency and the cold and heat storage materials placed in the low and high temperature chambers.

| NT551A | NT1251W | |
|---|---|---|
| Test area dimensions (W x H x D mm) |
370×330×400(48L) | 650×500×400×(130L) |
| load | 3.5kg | 7.5kg |
| IC 2.5kg + basket, receiver 1kg | IC 4.7kg + basket, receiver 2.8kg | |
| Low temperature recovery time | 53 seconds | 2 minutes 24 seconds |
| High temperature recovery time | 3 minutes 58 seconds | 3 minutes 5 seconds |
*The temperature recovery time is an actual measurement value, and the stated value is not a guaranteed value.

| Model | NT1251W | NT2051W |
|---|---|---|
| Test area dimensions (W x H x D mm) |
650×500×400×(130L) | 700×500×600×(210L) |
| load | 7.5kg | 26kg |
| IC 4.7kg + basket, receiver 2.8kg | IC 20kg + basket, receiver 6kg | |
| Low temperature recovery time | 46 seconds | 38 seconds |
| High temperature recovery time | 1 minute 5 seconds | 2 minutes |
*The temperature recovery time is an actual measurement value, and the stated value is not a guaranteed value.

A large sirocco fan maintains sufficient air circulation, ensuring excellent temperature distribution.

*The temperature distribution is an actual measurement, and the values shown are not guaranteed values.

WINTECH NEO is equipped with ECO mode, which has ETAC's unique learning function, and resumes pre-cooling/pre-heating at the optimal timing for each cycle.Compared to timer-type systems, there is no test interruption when refrigeration capacity drops, reducing unnecessary power consumption.

The temperature inside the chamber is automatically saved not only during operation, but also when it is stopped, such as when a problem occurs or after a power outage is restored, so the stress on the sample can be recorded without omission.
Operational data can be viewed on the monitor, and can also be downloaded in CSV format using a USB memory stick.
All models are equipped with a room temperature damper mechanism as standard, and are compatible with 3-zone standard tests such as MIL-STD-202G.


Hot gas temperature control prevents overcooling and significantly reduces frosting. Long-term continuous operation is possible without defrosting, significantly shortening test time. (Compared to our previous model: -40°C/30 minutes to +125°C/30 minutes, 2 zones)
*Calculated as: Electricity x 24 hours x 365 days x Operating rate 0.8 x 15 yen/kWh
[Varies depending on region, contract conditions, and time of use]
*When using hot gas control and ECO mode together

| Model | NT2051W |
|---|---|
| High temperature exposure | +125℃ 30 minutes |
| Low temperature exposure | −40℃ 30 minutes |
| Ambient temperature and humidity | +23℃ 60%Rh or less |
| cooling water temperature | +25℃ |
| Power supply voltage | AC200V 3φ 50/60Hz ±10% |
| Control Sensor | Downwind side of the test chamber |
| Sample (up to 10.0 kg) | Plastic mold IC: 7.0 kg Sample basket, receiving bracket: 3.0 kg |
| Temperature recovery time | Within 5 minutes |
The 300°C specification WINTECH series has been created for reliability evaluation of power devices for automotive and industrial use that require high voltage and current. The maximum preheating temperature is set at 350°C, allowing for ample testing at 300°C. Various basic parts have been redesigned to improve heat resistance and insulation performance during high-temperature operation. This series combines high performance and safety at a high level.
In addition to a highly efficient heat exchange circuit system and optimized cold/heat storage materials, ETAC's unique SR function enables temperature recovery in the shortest possible time.

SR function OFF
300℃→−40℃
Sample Aluminum piece 2.5kg
Windward temperature recovery time
9 minutes 22 seconds

SR function ON
300℃→−40℃
Sample Aluminum piece 2.5kg
Windward temperature recovery time
2 minutes 37 seconds
When transitioning from "high temperature exposure" to "low temperature exposure" during a two-zone test, the low temperature recovery time is significantly shortened by introducing outside air until the set temperature is reached. This is expected to have the effect of speeding up the temperature recovery time of the sample, especially under conditions with a wide temperature range or when under load.

SR function operating range

R Damper status and airflow during function operation
*Normal 2-zone testing is also possible.
*SR function only works when transitioning to low temperature exposure. Outside air intake does not work when transitioning to high temperature exposure.

Areas that are likely to become hot, such as the cable measurement hole, are insulated to prevent accidental contact with the device. A high level of safety is ensured down to the smallest details.
It can be installed on the back of the tester and can be easily replaced and cleaned. There is no need to remove the body panels, so it can be installed anywhere, even in a small space.

A large LED is used on top of the ETACOM to show the operating/abnormal status at a glance. The setting/display section uses a 7.5-inch wide color LCD with a touch panel, providing an intuitive and easy-to-understand interface while providing advanced programming functions.

Test room temperature data is automatically recorded at all times, even when test operation is not in progress. The recorded data can be viewed on the monitor to review past operation history.
Various graphics make it easy to check the program's progress and detailed information.
Various settings such as temperature, exposure time, number of cycles, etc. can be easily entered and edited.
Also, it is equipped with ETAC's unique setting functions, such as a built-in resettable counter that counts the elapsed cycles individually.
Sensors placed around the refrigerator constantly monitor the operating status. When a problem occurs, the operating status at that moment is automatically saved, allowing for a more accurate diagnosis of the cause of the failure and a quick recovery.
The "exposure time change function" has been added, which allows you to change the exposure time for low, high, and room temperatures during testing. In addition, the "specified cycle interruption function" has been added, which allows you to automatically interrupt the test after each set cycle.
| Model | NT551A | NT1051A | NT1251A | NT1051W | NT1251W | NT2051W |
|---|---|---|---|---|---|---|
| Freezer | Air-cooled | Air-cooled | Air-cooled | water cooled | water cooled | water cooled |
| Inner dimensions (W x H x D mm) | 370×330×400 | 370×500×400 | 650×500×400 | 370×500×400 | 650×500×400 | 700×500×600 |
| Contents (L) | 48 | 74 | 130 | 74 | 130 | 210 |
| Low temperature test temperature range | -65℃ to 0℃ | -65℃ to 0℃ | -65℃ to 0℃ | -65℃ to 0℃ | -65℃ to 0℃ | -65℃ to 0℃ |
| High temperature test temperature range | +60℃ to +200℃ | +60℃ to +200℃ | +60℃ to +200℃ | +60℃ to +200℃ | +60℃ to +200℃ | +60℃ to +200℃ |
| Pre-cooling temperature range | -75℃ to 0℃ | -75℃ to 0℃ | -75℃ to 0℃ | -80℃ to 0℃ | -80℃ to 0℃ | -80℃ to 0℃ |
| Preheating Temperature Range | +60℃ to +225℃ | +60℃ to +225℃ | +60℃ to +225℃ | +60℃ to +225℃ | +60℃ to +225℃ | +60℃ to +225℃ |
| Model | NT3702A | NT3702W |
|---|---|---|
| Freezer | Air-cooled | water cooled |
| Inner dimensions (W x H x D mm) | 370×450×400 | 370×450×400 |
| Contents (L) | 66 | 66 |
| Low temperature test temperature range | -65℃ to -10℃ | -65℃ to -10℃ |
| High temperature test temperature range | +80℃ to +300℃ | +80℃ to +300℃ |
| Pre-cooling temperature range | -75℃ to -20℃ | -75℃ to -20℃ |
| Preheating Temperature Range | +90℃ to +350℃ | +90℃ to +350℃ |